Note: If you have “AC” voltages, you can use our in-line bridge rectifier to convert to “DC” voltage. If you have 120 or 220 VAC, you will need to step down the voltage to 12 or 24 VAC along with using the in-line bridge rectifier.
- Natural gas flow capacities of 75,000 to 145,000 Btu/hr. at 1 inch pressure drop
- Optional Manual Override – reset gas valve if power is lost
- Body construction – Aluminum die or Sand cast
- Rated inlet pressure: 0.5 psi
- Available voltages: 12 VDC, 24 VDC
- Inlet/Outlet sizes: 1/4 inch, 3/8 inch
- Operable gas types: Natural Gas, Liquefied Petroleum (LP), LP gas-air mixtures
- Thermoelectric drop out range: 100 – 300 mA
- Permissible ambient (surface) temperature: -40° to 149°F (-40° to 65°C)
- UL Recognized
Documentation
Download Installation Instructions